Year 2016 / Volume 108 / Number 2
Original
Predictive factors of small bowel patency in Crohn's disease patients

65-70

DOI: 10.17235/reed.2015.3957/2015

Andreia Albuquerque, Hélder Cardoso, Margarida Marques, Susana Rodrigues, Filipe Vilas-Boas, Susana Lopes, Cláudia Camila Dias, Guilherme Macedo,

Abstract
Background: Patency capsule was developed to avoid small bowel video capsule endoscopy retention, namely in patients with Crohn’s disease. Aims: To evaluate the predictive factors of small bowel patency in Crohn’s disease patients. Patients and methods: Retrospective analysis including 151 Crohn’s disease patients submitted to patency capsule (Agile® Patency Capsule) from 2011 to 2012. Patients that excreted the intact patency capsule were classified as having a patent small bowel (without patency capsule retention), other patients were considered to have negative patency of the small bowel (patency capsule retention). Results: Patients had a mean age of 41±14 years, 54% were female and 25% had been previously submitted to surgery. Stricturing disease was seen in 20% of cases and penetrating disease in 16% of cases. Left-sided colonic lesions and ileal strictures were observed at colonoscopy in 13% and 9% of patients, respectively. In our sample, 28% of patients had negative patency of the small bowel (patency capsule retention). In multivariate analysis, independent factors that were associated with negative patency of the small bowel in Crohn’s disease patients were stricturing (OR 10.16, p < 0.001) and penetrating phenotypes (OR 11.73, p = 0.001), left-sided colonic lesions (OR 3.77, p = 0.038), ileal stricture (OR 9.76, p = 0.003); previous intestinal surgery was found to be protective (OR 0.16, p = 0.006). Conclusions: Stricturing or penetrating disease, ileal strictures, no previous surgery and left-sided colonic lesions were the factors associated with negative small bowel patency in Crohn’s disease patients.
Share Button
New comment
Comments
No comments for this article
References
1. Boivin ML, Lochs H, Voderholzer WA. Does passage of a patency capsule indicate small-bowel patency? A prospective clinical trial. Endoscopy. 2005; 37:808–15
2. Signorelli C, Rondonotti E, Villa F et al. Use of the Given Patency System for the screening of patients at high risk for capsule retention. Dig Liver Dis. 2006; 38:326–30
3. Spada C, Spera G, Riccioni M et al. A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule. Endoscopy. 2005; 37:793–800
4. Spada C, Riccioni ME, Costamagna G. The new, dissolving patency capsule: a safe and effective tool to avoid the complication of retained video capsules. J Clin Gastroenterol 2008; 42: 761-2
5. Caunedo-Alvarez A, Romero-Vazquez J, Herrerias-Gutierrez JM. Patency and Agile capsules. World J Gastroenterol. 2008; 14:5269-73
6. Cave D, Legnani P, de Franchis R, Lewis BS; ICCE. ICCE consensus for capsule retention. Endoscopy. 2005; 37:1065-7
7. Van Assche G, Dignass A, Panes J et al. The second European evidence-based consensus on the diagnosis and management of Crohn's disease: Definitions and diagnosis. J Crohns Colitis. 2010; 4:7-27
8. Cheifetz AS, Kornbluth AA, Legnani P et al. The risk of retention of the capsule endoscope in patients with known or suspected Crohn’s disease. Am J Gastroenterol 2006; 101:2218-22
9. Annese V, Daperno M, Rutter MD et al. European evidence based consensus for endoscopy in inflammatory bowel disease. J Crohns Colitis. 2013; 7:982-1018
10. Yadav A, Heigh RI, Hara AK et al. Performance of the patency capsule compared with nonenteroclysis radiologic examinations in patients with known or suspected intestinal strictures. Gastrointest Endosc 2011; 74:834–839
11. Herrerias JM, Leighton JA, Costamagna G et al. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy. Gastrointest Endosc 2008; 67:902-9
12. Postgate AJ, Burling D, Gupta A et al. Safety, reliability, and limitations of the Given patency capsule in patients at risk of capsule retention: a 3-year technical review. Dig Dis Sci 2008; 53:2732-8
13. Spada C, Shah SK, Riccioni ME et al.Video capsule endoscopy in patients with known or suspected small bowel stricture previously tested with the dissolving patency capsule. J Clin Gastroenterol. 2007; 41:576-82
14. Delvaux M, Ben Soussan E, Laurent V et al. Clinical evaluation of the use of the M2A patency capsule system before a capsule endoscopy procedure, in patients with known or suspected intestinal stenosis. Endoscopy. 2005; 37:801-7
15. Rieder F, Zimmermann EM, Remzi FH et al. Crohn's disease complicated by strictures: a systematic review. Gut. 2013; 62:1072-84
16. Louis E, Collard A, Oger AF et al. Behaviour of Crohn’s disease according to the Vienna classification: changing pattern over the course of the disease. Gut 2001; 49:777–82
17. Cosnes J, Cattan S, Blain A et al. Long-term evolution of disease behavior of Crohn’s disease. Inflamm Bowel Dis 2002; 8:244–50
18. Gasche C, Scholmerich J, Brynskov J et al. A simple classification of Crohn’s disease: report of the Working Party for the World Congresses of Gastroenterology, Vienna 1998. Inflamm Bowel Dis 2000; 6:8–15.
19. Fukumoto A, Tanaka S, Yamamoto H et al. Diagnosis and treatment of small-bowel stricture by double balloon endoscopy. Gastrointest Endosc 2007; 66: S108–12
20. Jürgens M, Brand S, Laubender RP et al. The presence of fistulas and NOD2 homozygosity strongly predict intestinal stenosis in Crohn’s disease independent of the IL23R genotype. J Gastroenterol 2010; 45:721–31
21. Oberhuber G, Stangl PC, Vogelsang H et al. Significant association of strictures and internal fistula formation in Crohn’s disease. Virchows Arch 2000; 437:293–7
22. Sheehan AL, Warren BF, Gear MW et al. Fat-wrapping in Crohn’s disease: pathological basis and relevance to surgical practice. Br J Surg 1992; 79:955–8
23. Van Assche G, Dignass A, Reinisch W et al. The second European evidence-based consensus on the diagnosis and management of Crohn's disease: Special situations. J Crohns Colitis. 2010; 4:63-101
24. Ciorba MA, Prakash C. Wireless capsule endoscopy in the diagnosis of small bowel Crohn's disease. Inflamm Bowel Dis. 2003; 9: 276
25. Biancone L, Onali S, Calabrese E et al. Non-invasive techniques for assessing postoperative recurrence in Crohn's disease. Dig Liver Dis. 2008; 40 (Suppl 2): S265-70
26. Buisson A, Chevaux JB, Bommelaer G et al. Diagnosis, prevention and treatment of postoperative Crohn's disease recurrence. Dig Liver Dis. 2012; 44:453-60
Related articles

Letter

Treatment with hyperbaric oxygen in a Crohn’s disease patient

DOI: 10.17235/reed.2024.10166/2023

Letter

Lung abscess in a non-compliant patient with Crohn’s disease

DOI: 10.17235/reed.2024.10140/2023

Letter

Coincidental oral lesions in Crohn’s disease

DOI: 10.17235/reed.2023.9992/2023

Letter

Duodenal stenosis surgical treatment in Crohn’s disease

DOI: 10.17235/reed.2023.9521/2023

Digestive Diseases Image

Peristomal cutaneous Crohn's disease by contiguity

DOI: 10.17235/reed.2022.8909/2022

Letter

Anal neoplasia and perianal Crohn’s disease: myth or reality?

DOI: 10.17235/reed.2021.8317/2021

Letter

Crohn’s disease in patients treated with etanercept

DOI: 10.17235/reed.2019.6554/2019

Original

Mercaptopurine and inflammatory bowel disease: the other thiopurine

DOI: 10.17235/reed.2016.4546/2016

Letter to the Editor

Adnexal localization of Crohn’s disease and recurrent massive ovary cysts

DOI: 10.17235/reed.2016.4301/2016

Case Report

Metastatic Crohn’s disease in pediatrics

DOI: 10.17235/reed.2016.3948/2015

Letter to the Editor

Crohn’s disease and Sweet’s syndrome: A debut together

DOI: 10.17235/reed.2015.3842/2015

Case Report

Ovarian involvement in Crohn´s disease: A rare complication

DOI: 10.17235/reed.2015.3764/2015

Citation tools
Albuquerque A, Cardoso H, Marques M, Rodrigues S, Vilas-Boas F, Lopes S, et all. Predictive factors of small bowel patency in Crohn's disease patients . 3957/2015


Download to a citation manager

Download the citation for this article by clicking on one of the following citation managers:

Metrics
This article has received 2123 visits.
This article has been downloaded 77 times.

Statistics from Dimensions


Statistics from Plum Analytics

Publication history

Received: 05/08/2015

Accepted: 30/09/2015

Online First: 23/11/2015

Published: 01/02/2016

Article revision time: 54 days

Article Online First time: 110 days

Article editing time: 180 days


Share
This article has been rated by 1 readers.
Reader rating:
Valora este artículo:




Asociación Española de Ecografía Digestiva Sociedad Española de Endoscopia Digestiva Sociedad Española de Patología Digestiva
The Spanish Journal of Gastroenterology is the official organ of the Sociedad Española de Patología Digestiva, the Sociedad Española de Endoscopia Digestiva and the Asociación Española de Ecografía Digestiva
Cookie policy Privacy Policy Legal Notice © Copyright 2024 y Creative Commons. The Spanish Journal of Gastroenterology