Year 2017 / Volume 109 / Number 5
Editorial
Is capsule colonoscopy the solution for incomplete conventional colonoscopy?

319-321

DOI: 10.17235/reed.2017.5018/2017

Miguel Mascarenhas-Saraiva,

Abstract
The era of colon capsule endoscopy (CCE) started in 2007. Few years later second-generation CCE (CCE-2) (Medtronic, Minneapolis, USA) was launched, featuring an improved optical system allowing for nearly 360° coverage via two 172° angle cameras, and adaptive frame rate function (ranging from 4 to 35 images per second depending on capsule motion). At present the main clinical indications for CCE are: a) completion of incomplete colonoscopy; b) polyp detection; and c) investigation of inflammatory bowel disease (IBD).
Share Button
New comment
Comments
No comments for this article
References
1. Van Gossum A, Munoz-Navas M, Fernandez-Urien I, et al. Capsule endoscopy versus colonoscopy for the detection of polyps and cancer. N Engl J Med 2009;361:264-70.
2. Spada C, Pasha SF, Gross SA, et al. Accuracy of first- and second-generation colon capsules in endoscopic detection of colorectal polyps: A systematic review and meta-analysis. Clin Gastroenterol Hepatol 2016; 14: 1533-43.
3. Belderbos TD, Grobbee EJ, van Oijen MG, et al. Comparison of cecal intubation and adenoma detection between hospitals can provide incentives to improve quality of colonoscopy. Endoscopy 2015; 47:703-9.
4. Rees CJ, Bevan R, Zimmermann-Fraedrich K, et al. Expert opinions and scientific evidence for colonoscopy key performance indicators. Gut 2016; 65: 2045– 2060.
5. Rex DK, Petrini JL, Baron TH, et al. Quality indicators for colonoscopy. Am J Gastroenterol 2006; 101: 873–85.
6. Baxter NN, Sutradhar R, Forbes SS, et al. Analysis of administrative data finds endoscopist quality measures associated with postcolonoscopy colorectal cancer. Gastroenterology 2011; 140: 65–72.
7. Morris EJA, Whitehouse LE, Farrell T, et al. A retrospective observational study examining the characteristics and outcomes of tumours diagnosed within and without of the English NHS Bowel Cancer Screening Programme. Br J Cancer 2012; 107: 757–64.
8. Tumino E, Parisi G, Bertoni M, et al. Use of robotic colonoscopy in patients with previous incomplete colonoscopy. Eur Rev Med Pharmacol Sci 2017; 21: 819-26.
9. Fernandes C, Pinho R, Pinto Pais T, et al. Colon capsule endoscopy after incomplete colonoscopy: Is it really useful and consensual? Gastrointest Endosc 2014; 79:1029-30.
10. Bick BL, Vemulapalli KC, Rex DK. Regional center for complex colonoscopy: Yield of neoplasia in patients with prior incomplete colonoscopy. Gastrointest Endosc 2016; 83: 1239-44.
11. Villa NA, Pannala R, Pasha SF, et al. Alternatives to Incomplete Colonoscopy. Curr Gastroenterol Rep 2015; 17:43.
12.Spada C, Stoker J, Alarcon O, et al. Clinical indications for computed tomographic colonography: European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastrointestinal and Abdominal Radiology (ESGAR) Guideline. Endoscopy. 2014; 46:897-915.
13. Lara LF, Avalos D, Huynh H, et al. The safety of same-day CT colonography following incomplete colonoscopy with Polypectomy. United European Gastroenterol J 2015; 3: 358-63.
14. Fernández-Urién I, Ostiz M, Jiménez J. Avoiding incomplete conventional colonoscopies: PillCamTM COLON capsule endoscopy. Rev Esp Enferm Dig 2011; 103: 389-91.
15. Spada C, Hassan C, Galmiche JP, et al. Colon capsule endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline. Endoscopy 2012; 44: 527-36.
16. Pioche M, De Leusse A, Filoche B, et al. Prospective multicenter evaluation of colon capsule examination indicated by colonoscopy failure or anesthesia contraindication. Endoscopy 2012; 44: 911-6.
17. Nogales O, Lujan M, Nicolas D, et al. Utility of colon capsule endoscopy after an incomplete colonoscopy. Multicentric Spanish study. United European Gastroenterol J 2013; 1:A344.
18.Alarcón-Fernández O, Ramos L, Adrián-de-Ganzo Z, et al. Effects of colon capsule endoscopy on medical decision making in patients with incomplete colonoscopies. Clin Gastroenterol Hepatol 2013; 11: 534-40.
19. Triantafyllou K, Viazis N, Tsibouris P, et al. Colon capsule endoscopy is feasible to perform after incomplete colonoscopy and guides further workup in clinical practice. Gastrointest Endosc 2014; 79: 307-16.
20. Baltes P, Bota M, Albert JG, et al. Tu1557 PillCam Colon2® After Incomplete Colonoscopy- a Prospective Multi-Center Study. Gastrointest Endosc 2014; 79: AB584.
21. Spada C, Hassan C, Barbaro B, et al. Colon capsule versus CT colonography in patients with incomplete colonoscopy: a prospective, comparative trial. Gut 2015; 64: 272–81.
22. Yung DE, Rondonotti E, Koulaouzidis A. Review: capsule colonoscopy—a concise clinical overview of current status. Ann Transl Med 2016; 4:398
23. Nogales O, García-Lledó J, Luján Ml, et al. Therapeutic impact of colon capsule endoscopy with PillCam™ COLON 2 after incomplete standard colonoscopy: a Spanish multicenter study. Rev Esp Enferm Dig 2017.doi:10.17235/reed.2017.4369/2016.
24. Togashi K, Fujita T, Utano K, et al. Gastrografin as an alternative booster to sodium phosphate in colon capsule endoscopy: safety and efficacy pilot study. Endosc Int Open. 2015 ; 3: E659-61
25. Singhal S, Nigar S, Paleti V, et al. Bowel preparation regimens for colon capsule endoscopy: a review. Therapeutic Advances in Gastroenterology. 2014; 7: 115-22.
26. Arguelles-Arias F, San-Juan-Acosta M, Belda A, et al. Preparations for capsule endoscopy. Prospective and randomized comparative study between two preparations for colon capsule endoscopy: PEG 2 litres + ascorbic acid versus PEG 4 litres. Rev Esp Enferm Dig 2014; 106: 312-7.
27. Jiménez-Garcia VA, Arguelles-Arias F, Romero-Vásquez J, et al. Comparative study of three protocol to cathartic preparation for the study of colon by PillCam Colon. Gastroenterology 2014: 146: S-771.
28. Romero-Vázquez J, Caunedo-Álvarez Á, Belda-Cuesta A, et al. Extracolonic findings with the PillCam Colon: is panendoscopy with capsule endoscopy closer? Endosc Int Open. 2016 Oct; 4(10): E1045–E1051
Related articles

Digestive Diseases Image

Underwater polypectomy at the appendiceal orifice in a patient on anticoagulation

DOI: 10.17235/reed.2023.9842/2023

Letter

An uncommon colonic polyp

DOI: 10.17235/reed.2022.9160/2022

Digestive Diseases Image

Intestinal obstruction due to bariolith impaction

DOI: 10.17235/reed.2022.9084/2022

Letter

Anorectal malignant melanoma, a diagnostic challenge

DOI: 10.17235/reed.2022.9068/2022

Letter

Lead ingestion, medical emergency and action plan

DOI: 10.17235/reed.2022.9048/2022

Letter

Endoscopic findings of radiation ileitis

DOI: 10.17235/reed.2022.9036/2022

Letter

Endoscopic imaging of pneumatosis intestinalis

DOI: 10.17235/reed.2022.8972/2022

Editorial

Colonoscopy — When quality matters

DOI: 10.17235/reed.2022.8942/2022

Digestive Diseases Image

Colonic Kaposi’s sarcoma as the first clinical manifestation of undiagnosed HIV

DOI: 10.17235/reed.2022.8717/2022

Letter

Gastrointestinal lymphoma, a rare endoscopic lesion

DOI: 10.17235/reed.2022.8555/2021

Letter

Cecal MALT lymphoma: a challenging diagnosis

DOI: 10.17235/reed.2021.8526/2021

Letter

Surprises in cecal intubation: foreign bodies in the colon

DOI: 10.17235/reed.2021.8155/2021

Digestive Diseases Image

Phlebosclerotic colitis: an unusual cause of abdominal pain and hematochezia

DOI: 10.17235/reed.2020.7358/2020

Case Report

Primary colon mantle lymphoma: a misleading macroscopic appearance!

DOI: 10.17235/reed.2019.6405/2019

Digestive Diseases Image

Colorectal penetration by two intrauterine devices

DOI: 10.17235/reed.2019.5974/2018

Editorial

Colorectal cancer screening and survival

DOI: 10.17235/reed.2018.5870/2018

Letter

Bacterial endogenous endophthalmitis after colonoscopy

DOI: 10.17235/reed.2018.5658/2018

Review

Quality indicators in colonoscopy. The colonoscopy procedure

DOI: 10.17235/reed.2018.5408/2017

Letter to the Editor

A rare complication after colonoscopy: a splenic rupture

DOI: 10.17235/reed.2018.5362/2017

Letter to the Editor

Acute appendicitis after a colonic endoscopic submucosal resection

DOI: 10.17235/reed.2018.5307/2017

Digestive Diseases Image

Contribution of the virtual colonoscopy in a case of intestinal intussusception

DOI: 10.17235/reed.2017.5261/2017

Digestive Diseases Image

A bull horn fragment found on colonoscopy

DOI: 10.17235/reed.2017.5020/2017

Editorial

Issue pending: minimizing anxiety before colonoscopy

DOI: 10.17235/reed.2016.4756/2016

Digestive Diseases Image

Intrauterine device in the rectal cavity

Letter to the Editor

Primary chancre in the rectum: an underdiagnosed cause of rectal ulcer

DOI: 10.17235/reed.2017.4457/2016

Digestive Diseases Image

Pneumatosis cystoides intestinalis

Letter to the Editor

Splenic rupture after colorectal cancer screening

DOI: 10.17235/reed.2015.3714/2015

Citation tools
Mascarenhas-Saraiva M. Is capsule colonoscopy the solution for incomplete conventional colonoscopy?. 5018/2017


Download to a citation manager

Download the citation for this article by clicking on one of the following citation managers:

Metrics
This article has received 1012 visits.
This article has been downloaded 249 times.

Statistics from Dimensions


Statistics from Plum Analytics

Publication history

Received: 18/04/2017

Accepted: 19/04/2017

Online First: 21/04/2017

Published: 03/05/2017

Article Online First time: 3 days

Article editing time: 15 days


Share
This article hasn't been rated yet.
Reader rating:
Valora este artículo:




Asociación Española de Ecografía Digestiva Sociedad Española de Endoscopia Digestiva Sociedad Española de Patología Digestiva
The Spanish Journal of Gastroenterology is the official organ of the Sociedad Española de Patología Digestiva, the Sociedad Española de Endoscopia Digestiva and the Asociación Española de Ecografía Digestiva
Cookie policy Privacy Policy Legal Notice © Copyright 2024 y Creative Commons. The Spanish Journal of Gastroenterology