Year 2019 / Volume 111 / Number 6
Editorial
Endoscopic ultrasound-guided drainage with lumen-apposing metal stents: a good safety profile also in the long term?

416-418

DOI: 10.17235/reed.2019.6348/2019

Enrique Pérez-Cuadrado Robles, Frédéric Prat, Pierre H. Deprez,

Abstract
Lumen-apposing metal stents (LAMSs) have been specifically designed for the endoscopic drainage of pancreatic fluid collections and walled-off necrosis. Lately, LAMS indications have expandedto other anastomoses, and these stents have proven to be effective in multiple situations. Safety data for this device are still limited, most studies to date being focused on intraoperative complications and not long-term issues. There are little data regarding the best timing for removal and the risks associated in leaving them in place for long duration. In addition, not all the procedure-related complications have the same clinical impact, and the settings in which LAMS have been used are heterogeneous, leading to different safety profiles and outcomes. A wide consensus on the definition of complications and a list of key performance measures for LAMS placement seems mandatory to allow for a robust assessment of their long-term outcomes.
Share Button
New comment
Comments
No comments for this article
References
[1] Saumoy M, Yarber C, Kahaleh M. Novel Uses of Lumen-Apposing Metal Stents. Gastrointest Endosc Clin N Am. 2018; 28(2):197-205. doi: 10.1016/j.giec.2017.11.007.
[2] Larson B, Adler DG. Lumen-apposing metal stents for gastrointestinal luminal strictures: current use and future directions. Ann Gastroenterol. 2019; 32(2):141-146. doi: 10.20524/aog.2018.0337.
[3] Amateau SK, Lim CH, McDonald NM et al. EUS-Guided Endoscopic Gastrointestinal Anastomosis with Lumen-Apposing Metal Stent: Feasibility, Safety, and Efficacy. Obes Surg. 2018; 28(5):1445-1451. doi: 10.1007/s11695-018-3171-6.
[4] Arvanitakis M, Dumonceau JM, Albert J et al. Endoscopic management of acute necrotizing pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) evidence-based multidisciplinary guidelines. Endoscopy. 2018; 50(5):524-546. doi: 10.1055/a-0588-5365.
[5] Bang JY, Navaneethan U, Hasan MK et al. Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut. 2018 Jun 1. pii: gutjnl-2017-315335. doi: 10.1136/gutjnl-2017-315335.
[6] Chen YI, Yang J, Friedland S et al. Lumen apposing metal stents are superior to plastic stents in pancreatic walled-off necrosis: a large international multicenter study. Endosc Int Open. 2019; 7(3):E347-E354. doi: 10.1055/a-0828-7630.
[7] Chen YI, Barkun AN, Adam V et al. Cost-effectiveness analysis comparing lumen-apposing metal stents with plastic stents in the management of pancreatic walled-off necrosis. Gastrointest Endosc. 2018; 88(2):267-276.e1. doi: 10.1016/j.gie.2018.03.021.
[8] Mussetto A, Fugazza A, Fuccio L et al. Current uses and outcomes of lumen-apposing metal stents. Ann Gastroenterol. 2018 ; 31(5):535-540. doi: 10.20524/aog.2018.0287.
[9] Hammad T, Khan MA, Alastal Y et al. Efficacy and Safety of Lumen-Apposing Metal Stents in Management of Pancreatic Fluid Collections: Are They Better Than Plastic Stents? A Systematic Review and Meta-Analysis. Dig Dis Sci. 2018; 63(2):289-301.
[10] Lang GD, Fritz C, Bhat T. EUS-guided drainage of peripancreatic fluid collections with lumen-apposing metal stents and plastic double-pigtail stents: comparison of efficacy and adverse event rates. Gastrointest Endosc. 2018; 87(1):150-157. doi: 10.1016/j.gie.2017.06.029.
[11] Bazaga Pérez de Rozas S, Yaiza Carbajo A, García-Alonso FJ et al. A retrospective, multicenter analysis of incidents associated with Axios lumen-apposing stents. Rev Esp Enferm Dig. 2019. In press.
[12] Amateau SK, Freeman ML. Avoidance, Recognition, and Management of Complications Associated with Lumen-Apposing Metal Stents. Gastrointest Endosc Clin N Am. 2018; 28(2):219-231. doi: 10.1016/j.giec.2017.11.009.
[13] Garcia-Alonso FJ, Sanchez-Ocana R, Peñas-Herrero I et al. Cumulative risks of stent migration and gastrointestinal bleeding in patients with lumen-apposing metal stents. Endoscopy. 2018; 50(4):386-395. doi: 10.1055/a-0581-9040.
[14] Petrone MC, Archibugi L, Forti E et al. Novel lumen-apposing metal stent for the drainage of pancreatic fluid collections: An Italian multicentre experience. United European Gastroenterol J. 2018; 6(9):1363-1371. doi: 10.1177/2050640618785078.
[15] Yang D, Perbtani YB, Mramba LK et al. Safety and rate of delayed adverse events with lumen-apposing metal stents (LAMS) for pancreatic fluid collections: a multicenter study. Endosc Int Open. 2018; 6(10):E1267-E1275. doi: 10.1055/a-0732-502.
[16] Siddiqui AA, Adler DG, Nieto J et al. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos). Gastrointest Endosc. 2016; 83(4):699-707. doi: 10.1016/j.gie.2015.10.020.
[17] Sevilla-Ribota S, Garcia-Alonso FJ, Sánchez-Ocaña R et al. Technical issues during EUS-guided placement of lumen apposing metal stents: definition and classification, incidence and risk factors, endoscopic management and effect on procedure outcomes. United European Gastroenterol J. 2018; 6 (Supplement 1).
Related articles

Letter

Duodenal lymphangiomas: endoscopic ultrasound features

DOI: 10.17235/reed.2024.10338/2024

Digestive Diseases Image

Imaging of pancreatic desmoid fibromatosis by endoscopic ultrasound

DOI: 10.17235/reed.2023.9792/2023

Letter

Acute cholecystitis treated by direct visualization endoscopy

DOI: 10.17235/reed.2023.9432/2022

Digestive Diseases Image

Endosonographic and ERCP findings in COVID-19 critical illness cholangiopathy

DOI: 10.17235/reed.2022.9218/2022

Letter

Angiosarcoma of the aorta diagnosed via endoscopic ultrasound

DOI: 10.17235/reed.2022.8879/2022

Digestive Diseases Image

Pancreatic lymphoma during pregnancy

DOI: 10.17235/reed.2022.8811/2022

Digestive Diseases Image

When needles are not enough, forceps delivers!

DOI: 10.17235/reed.2022.8697/2022

Letter

Lumen-apposing metal stent deployment failure

DOI: 10.17235/reed.2020.7060/2020

Editorial

Guessing the future of endoscopic drainage of walled-off necrosis

DOI: 10.17235/reed.2020.7252/2020

Review

Management of pancreatic collections: an update

DOI: 10.17235/reed.2020.6814/2019

Digestive Diseases Image

Endoscopic therapy in disconnected duct syndrome: re-connecting the duct

DOI: 10.17235/reed.2020.6650/2019

Letter

A giant liver abscess due to Fasciola hepatica infection

DOI: 10.17235/reed.2019.6136/2018

Digestive Diseases Image

Cumbersome removal of an endoscopic nasobiliary drainage tube

DOI: 10.17235/reed.2019.5962/2018

Letter

Sometimes things are what they seem

DOI: 10.17235/reed.2019.5911/2018

Digestive Diseases Image

A rare case of acute obstructive suppurative pancreatic ductitis associated with ERCP

DOI: 10.17235/reed.2018.5756/2018

Letter

A giant abdominal collection: when things are not what they seem

DOI: 10.17235/reed.2018.5642/2018

Letter to the Editor

Late migration of a metal stent after EUS-drainage of a pancreatic pseudocyst abscess

DOI: 10.17235/reed.2018.5411/2017

Letter to the Editor

EUS-guided ethanol ablation therapy for gastric stromal tumors

DOI: 10.17235/reed.2017.5361/2017

Letter to the Editor

A rectal neuroendocrine neoplasm

DOI: 10.17235/reed.2017.4836/2017

Review

Endoscopic ampullectomy: a technical review

DOI: 10.17235/reed.2016.3867/2015

Case Report

Pelvic inflammatory myofibroblastic tumor mimicking a rectal cancer

DOI: 10.17235/reed.2015.3777/2015

Citation tools
Pérez-Cuadrado Robles E, Prat F, Deprez P. Endoscopic ultrasound-guided drainage with lumen-apposing metal stents: a good safety profile also in the long term?. 6348/2019


Download to a citation manager

Download the citation for this article by clicking on one of the following citation managers:

Metrics
This article has received 1231 visits.
This article has been downloaded 178 times.

Statistics from Dimensions


Statistics from Plum Analytics

Publication history

Received: 19/04/2019

Accepted: 23/04/2019

Online First: 13/05/2019

Published: 07/06/2019

Article Online First time: 24 days

Article editing time: 49 days


Share
This article hasn't been rated yet.
Reader rating:
Valora este artículo:




Asociación Española de Ecografía Digestiva Sociedad Española de Endoscopia Digestiva Sociedad Española de Patología Digestiva
The Spanish Journal of Gastroenterology is the official organ of the Sociedad Española de Patología Digestiva, the Sociedad Española de Endoscopia Digestiva and the Asociación Española de Ecografía Digestiva
Cookie policy Privacy Policy Legal Notice © Copyright 2024 y Creative Commons. The Spanish Journal of Gastroenterology